380 V Air Source Central Heating System Apply To Heat House / Apartment / Office

Ask Latest Price
Brand Name :Yushen
Model Number :SDNA-075Y, SDNA-090YB
Certification :CCC, ISO, CQC
Place of Origin :China
MOQ :1 set
Price :negotiable
Payment Terms :T/T
Supply Ability :10 sets/day
Delivery Time :1-2 weeks
Packaging Details :Reinforced Carton box with wooden tray
Key word :central Air Source Heat Pump
Compressor capacity :25HP to 30HP per set
Function :Heating
Size :2100×1100×2080mm
Weight :730Kg
Compressor :Copeland
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

37Kw ~ 90Kw Air Source Central Heating System To Heat House, Apartment , Office

ASHPs Features

1. Central heating station, the control of every room could be seperated.

2.It is 40% enegy-saving than electric conventional Air conditioner unit.

3.No pollution, clean and environmental friendly

4.Control complete operation, advanced intelligent control system, with compressor protection, high voltage protection, low voltage protection, water shortage protection, leakage protection, lack of protection, overload protection, antifreeze protection, excessive exhaust temperature protection. The comprehensive protection function principle is convenient and simple.

5. Many sets could be connected parallel according to the service area.

6.Widely used, the products have different specifications series, which can meet the heating of factories, hotels, schools, hospitals, beauty salons, bathing centers, villas, homes, etc.

.

Heating model code name.pdf

Model SDNA-075Y SDNA-090YB
Compressor capacity 25HP 30HP
Function Heat Heat
Electricity 380V 3N-50Hz 380V 3N-50Hz
Working conditions -25~+45 -25~+45
Data Heata Nominal capacity KW 44.5 56.2
Input power KW 18.3 23.4
COP / 2.4 2.4
Heating IPLV(H) 2.7 2.7
A7W35c KW/COP 75.0/4.2 90.0/4.2
A2W35 KW/COP 62.5/3.20 79.0/3.20
A-7W35 KW/COP 52.5/3.0 63.2/3.0
A-15W55 KW/COP 45.5 /1.97 56.2/1.97
A-20W45 KW/COP 37.4/2.04 47.2/2.04
Max. running currency A 56 70
Compressor quantity set 2 4
Refrigerant/charging quantity kg / R22/10*2 R22/5*4
Air blow type / Top Top
Water pipe diameter mm 50 50
Rating flow m³/h 12.6 12.6
Water side pressure loss kPa ≤45 ≤45
Noise level dB(A) 62 62
Overall dimensions(L×W×H) mm 2100×1100×2080 2100×1100×2080
Weight kg 730 830

Yushen Products

  • It could work in extreme environment /Suitable for environmental temperature:-25℃ to +45 ℃ /-13℉ to 113 ℉
  • Yushen air source heat pump is 35% more powerful than other products, long heating time and less defrosting time
  • No capacity decay under low temperature, keep high COP in winter
  • Quality Components such as Copeland compressor, Danfoss valves
  • Pay attention to details such as every stainless-steel screw has cushion to prevent from water corrosion
  • Clean and clear wiring and lining
  • 100% finished products testing
  • Having only one unit which could both heat and cool to maintain means lower repair costs and less work in general.

Is an ASHPs suitable for me?

  • Do you have somewhere to put it? central heating station need a place where a unit can be fitted to the top of building or placed on the ground. It will need plenty of space around it to get a good flow of air.
  • Is the building well insulated? Since air source heat pumps work best when producing heat at a lower temperature than traditional boilers, it's essential that your home is well insulated and draught-proofed for the heating system to be most efficient.
  • What fuel will you be replacing? The system will pay for itself much more quickly if it's replacing an electricity or coal heating system.
  • What type of heating system will you use? Air source heat pumps can perform better with underfloor heating systems or warm air heating .
  • Is the system intended for a new development? Combining the installation with other building work can reduce the cost of installing the system.
  • Dose the local goverment have incentive? Some coutries have incentive to enviromental friendly products.

Inquiry Cart 0