7KW Mini Split Heat Pump Cold Climate Air Conditioner Fan Outdoor Unit
Feature
Technical data
Model | SLNA-007UMcode name.pdf | |||
Compressor capacity | 2HP | |||
Function | Heating and Cooling | |||
Electricity | 220V-1N-50Hz | |||
Working conditions | ℃ | -25~~+45 | ||
Data | Heata | Nominal capacity | KW | 3.9 |
Input power | KW | 1.69 | ||
COP | / | 2.3 | ||
Heating IPLV(H) | 2.53 | |||
Coolb | Nominal capacity | KW | 4.4 | |
Input power | KW | 1.69 | ||
COP | / | 2.6 | ||
Cooling IPLV(C) | 2.7 | |||
A7W35c | KW/COP | 6.4/4.1 | ||
A2W35 | KW/COP | 5.8/3.6 | ||
A-7W35 | KW/COP | 4.3/2.7 | ||
A-15W55 | KW/COP | 3.4/1.9 | ||
A-20W45 | KW/COP | 2.9/1.94 | ||
Max. running currency | A | 13.2 | ||
Compressor quantity | set | 1 | ||
Refrigerant/charging quantity kg | / | R404A/2.2 | ||
Air blow type | / | Side | ||
Water pipe diameter | inch | G1〞 | ||
Rating flow | m³/h | 1.6 | ||
Water side pressure loss | kPa | ≤35 | ||
Noise level | dB(A) | 59 | ||
Overall dimensions(L×W×H) | mm | 1087×435×901 | ||
Weight | kg | 70 |
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
Applications
House, apartment, villa air heating or cooling.
In summer, it provide 7C cool water and in winter, it provide 50C hot water
Water could be used in bath too.
ASHP VS Air Conditioner unit
The air source heat pump air conditioner belongs to the central air conditioner of the water system. It uses water circulation refrigeration, and the outlet air temperature is high and soft. The temperature difference with the outdoor is not too large, and it is not punctured when it is blown on the body. At the same time, it can maintain the best indoor humidity environment and avoid indoor drying. The air conditioner is a fluorine system. The main purpose of the air conditioner at the beginning of the design is cooling. Therefore, the accessories of the airframe are designed for cooling. The air conditioner has a relatively high energy efficiency conversion during cooling, and the air temperature is relatively low. It will be relatively large, the interior will be relatively dry, and it will be chilly when it is blown to the body, and the cooling will be faster.