Add to Cart
Silent 2HP Home Use Air Source Heat Pump for Radiators Heating
Feature
1. 59Dba silence running outdoor
2. compact size, suitable for wall or floor mouted
3.Highly automated , easy operation as AC
4. It could both heating and cooling
5. It could also provides hot water and cool water for home use
Technical data
Model | SLNA-007UMcode name.pdf | |||
Compressor capacity | 2HP | |||
Function | Heating and Cooling | |||
Electricity | 220V-1N-50Hz | |||
Working conditions | ℃ | -25~~+45 | ||
Data | Heata | Nominal capacity | KW | 3.9 |
Input power | KW | 1.69 | ||
COP | / | 2.3 | ||
Heating IPLV(H) | 2.53 | |||
Coolb | Nominal capacity | KW | 4.4 | |
Input power | KW | 1.69 | ||
COP | / | 2.6 | ||
Cooling IPLV(C) | 2.7 | |||
A7W35c | KW/COP | 6.4/4.1 | ||
A2W35 | KW/COP | 5.8/3.6 | ||
A-7W35 | KW/COP | 4.3/2.7 | ||
A-15W55 | KW/COP | 3.4/1.9 | ||
A-20W45 | KW/COP | 2.9/1.94 | ||
Max. running currency | A | 13.2 | ||
Compressor quantity | set | 1 | ||
Refrigerant/charging quantity kg | / | R404A/2.2 | ||
Air blow type | / | Side | ||
Water pipe diameter | inch | G1〞 | ||
Rating flow | m³/h | 1.6 | ||
Water side pressure loss | kPa | ≤35 | ||
Noise level | dB(A) | 59 | ||
Overall dimensions(L×W×H) | mm | 1087×435×901 | ||
Weight | kg | 70 |
Model data base
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
Advantages of Air source heat pump
1,Air source heat pump VS Electric air conditioner unit
Items | Air source heat pump | Air conditioner unit |
When heating | 40% energy saving than Ac | --- |
When cooling | Equal energy consumption | Equal |
Installation | Easy | easy |
Maintenance | Little | some |
Suitable for Ender | AC fans, under floor,radiator | AC fans only |
Extra | Hot water | no |
2. Air source heat pump VS gas furnace
Gas water heaters have the problem of gas poisoning. Compared with this type of water heater, the air energy heat pump avoids the direct contact between the electric heating element and the water through the medium heat exchange, thus solving the leakage potential of the electric water heater, and secondly, because of the raw materials. It is air, so it also eliminates the possibility of gas explosion or gas poisoning in gas water heaters, making people more comfortable and worry-free.