Add to Cart
Portable Air Source Heat Pump , Air To Air Heat Pumps In Cold Climates
Air Source Heat Pump Features:
1. copelan* EVI scroll ZWKSE series compressor and environmentally friendly refrigerant R407C, stable working at -25dC ambient temperature.
2. Heat exchanger use high efficient tank heat exchanger for heating/hot water. use stainless steel plate heat exchanger for heating/cooling.
3. Automatical defrost functional and power-off memory function.
4. Intelligent microcomputer control system with LCD panel, can mannually,automatically switch unit on/off, timer switch unit on/off, fault alarm, fault code display.
5. Multifunctional self-protection:
Phase sequence protection, high and low pressure protection, current protection, high and low temperature protection, antifreeze protection...
6. Add chassis electric heater to avoide condensate water freezes in winter.
<iframe width="644" height="362" src="https://www.youtube.com/embed/GB8boMVWi8I" frameborder="0" allow="accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe>
Air Source Heat Pump Parameter
Model | SDNA-090YB Inverter Air Source Heat Pump code name.pdf | |||
Compressor capacity | 30HP | |||
Function | Heat | |||
Electricity | 380V 3N-50Hz | |||
Working conditions | ℃ | -25~+45 | ||
Data | Heata | Nominal capacity | KW | 56.2 |
Input power | KW | 23.4 | ||
COP | / | 2.4 | ||
Heating IPLV(H) | 2.7 | |||
A7W35c | KW/COP | 90.0/4.2 | ||
A2W35 | KW/COP | 79.0/3.20 | ||
A-7W35 | KW/COP | 63.2/3.0 | ||
A-15W55 | KW/COP | 56.2/1.97 | ||
A-20W45 | KW/COP | 47.2/2.04 | ||
Max. running currency | A | 70 | ||
Compressor quantity | set | 4 | ||
Refrigerant/charging quantity kg | / | R22/5*4 | ||
Air blow type | / | Top | ||
Water pipe diameter | mm | 50 | ||
Rating flow | m³/h | 12.6 | ||
Water side pressure loss | kPa | ≤45 | ||
Noise level | dB(A) | 62 | ||
Overall dimensions(L×W×H) | mm | 2100×1100×2080 | ||
Weight | kg | 830 |
Air Source Heat Pump description
Yushen Products Features
Service